CÔNG TY TNHH KỸ THUẬT CÔNG NGHỆ HPC

✅ Chuyên nhập khẩu, phân phối, cho thuê máy phát điện
✅ Chuyên phụ tùng Caterpillar-Cummins-Mitsubishi-Johndeere

0908.577.177

hiep@hpc-vn.com

ĐẦU PHÁT LEROY SOMER LSA 47.3

Mã sản phẩm: LSA 47.3

Nhà sản xuất: Leroy somer

Công suất : 410 – 660 kVA

Description

ĐẦU PHÁT LEROY SOMER LSA 47.3

Leroy somer performance:

Leroy Somer LSA 47.3 alternator has been designed to offer you the best power generation performances. With its meticulous design and optimized architecture, the LSA 47.3 strikes the perfect balance between compactness, reliability, performance and longevity.

Whatever your application, the LSA 47.3 will meet your needs and will adapt to all situations.

Standards:

Leroy Somer LSA 47.3 alternator meets all key international standards and regulations, including IEC 60034, NEMA MG 1.32-33, ISO 8528-3, CSA C22.2 n°100-14 and UL 1446 (UL 1004 on request). Also compliant with IEC 61000-6-2,

IEC 61000-6-3, IEC 61000-6-4, VDE 0875G, VDE 0875N and EN 55011, group 1 class A for European zone.

Nidec Leroy Somer LSA 47.3 alternator can be integrated in EC marked generator set, and bears EC, EAC and CMIM markings. It is designed, manufactured and marketed in an ISO 9001 and ISO 14001 quality assurance environment.

Electrical characteristics and performances:

Class H insulation, 2/3 pitch winding, standard 12-wire (6) reconnectable

Voltage range:

– 50 Hz: 220V – 240V and 380V – 415V (440V)

– 60 Hz: 208V – 240V and 380V – 480V

High efficiency and motor starting capacity

Other voltages are possible with optional adapted windings:

– 50 Hz: 440V (no. 7), 500V (no. 9), 550V (no. 22 or 23), 600V (no. 22 or 23), 690V (no. 10 or 52)

– 60 Hz: 380V and 416V (no. 8), 600V (no. 9), 690V (no. 22 or 23)

Excitation and regulation system

*: only with AREP or PMG, phase sensing is included as a standard with digital

Protection system and options:

The LSA 47.3 is IP 23

Complete winding protection for clean environments with relative humidity ≤ 95 %, including indoor marine environments

Options:

  • Filters on air inlet: derating 5%
  • Filters on air inlet and air outlet (IP 44): derating 10%
  • Reinforced winding protection for harsh environments and relative humidity greater than 95%
  • Space heater
  • Thermal protection for stator windings and shields

Mechanical construction:

  • Compact and rigid assembly to better withstand generator vibrations
  • Steel frame
  • Cast iron flanges and shields
  • Two-bearing and single-bearing versions designed to be suitable for engines on the market
  • Half-key balancing
  • Greased for life bearings, regreasable bearings (optional)
  • Standard direction of rotation: clockwise when looking at the drive end view (for anti-clockwise, derate the machine by 5%)

Terminal box design:

  • Easy access to the voltage regulator and to the connections
  • Possible inclusion of accessories for paralleling, protection and measurement
  • 9-way terminal block for voltage reconnection

General characteristics:

Insulation class H Excitation system SHUNT AREP / PMG
Winding pitch 2/3 (wind. 6) AVR type R250 D350
Number of wires 12 Voltage regulation (*) ± 0.5% ± 0.25%
Protection IP 23 Short-circuit current 300% (3 IN) : 10s
Altitude ≤ 1000 m Total Harmonic Distortion THD (**) no load < 1.5% – on load < 2%
Overspeed 2250 R.P.M. Waveform: NEMA = TIF (**) < 50
Air flow 0.9 m3/s (50 Hz) / 1.1 m3/s (60 Hz) Waveform: I.E.C. = THF (**) < 2%

(**) Total harmonic distortion between phases, no-load or on-load (non-distorting)

Power 410 – 660 kVA*
Voltage 220 – 480V
Poles 4
Speed 1500 – 1800 rpm
Shaft height 355 mm
Max efficiency 95.2 %
Excitation SHUNT / AREP / PMG
Regulation R250 / D350 / D550

(* kVA/50Hz – kW/60Hz | Continuous / 40°C (Discrepancies may occur, consult catalogue for exact figures)

Insulation class H
Winding pitch 2/3 (winding 6)
Number of wires 12 (optional 6 wires)
Protection IP 23
Altitude ≤ 1000 m
Overspeed 2250 rpm
Air flow 0.9 m3/s (50Hz) / 1.1m3/s(60Hz)
Excitation system / AVR type SHUNT/R250 AREP or PMG/D350
Voltage regulation (Steady state) ±0.5% SHUNT / ±0.25% AREP
Short-circuit current (3 IN / 10 s) 300 % (3 IN) : 10s
Regulators:
Regulators R250 D350 D550
Mains Paralleling
3-phase sensing
Advanced settings
Data logging & monitoring
Remote communication
Remote voltage potentiometer
CT for paralleling
R791 RFI suppression kit (standard in Europe)

● : Included             ○ : Option             – : Not available

Flex plate / Flange:
Flex plate / Flange 1 1/2 0
11 ½
14
18

Reviews

There are no reviews yet.

Be the first to review “ĐẦU PHÁT LEROY SOMER LSA 47.3”